A fix is available
APAR status
Closed as program error.
Error description
The COBOL Programming Guide continues to document the use of IGZCA2D (MBCS to DBCS conversion) and IGZCD2A (DBCS to MBCS conversion), however these modules have dependencies on code generated by COBOL v4 and earlier, as well as on data structures used by the corresponding run-time. This causes them to fail with an ABEND0C1 when used from COBOL v5 and later compiled code.
Local fix
Write COBOL v4 wrappers
Problem summary
**************************************************************** * USERS AFFECTED: Enterprise COBOL V5+ users running programs * * that CALL services IGZCA2D or IGZCD2A. * * * **************************************************************** * PROBLEM DESCRIPTION: Runtime ABEND S0C1 when IGZCA2D or * * IGZCD2A is called by a COBOL program * * compiled with Enterprise COBOL V5+. * * * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** Existing entry points, IGZCA2D and IGZCD2A, could not process CALLs from programs compiled with COBOL V5 or later.
Problem conclusion
This APAR corrects the runtime entry points IGZCA2D or IGZCD2A so that they can function properly when called by a COBOL program compiled with Enterprise COBOL V5+. This APAR works in conjunction with APAR PI62381. FIXCAT keyword: COB0501T/K COB0502T/K COB0601T/K
Temporary fix
Comments
APAR Information
APAR number
PI62718
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
790
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-05-18
Closed date
2016-05-25
Last modified date
2016-07-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI38154 UI38155
Modules/Macros
IGZCEV4 IGZLLIBV IGZXAPI IGZXDMR IGZXD24 IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG IGZXPK2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCVR7X","label":"Runtime"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]
Document Information
Modified date: