IBM Support

PI62695: SPACES IN THE QUEUE NAME FIELD OF A MESSAGE ACTION CAUSE THE FIELD TO BE BLANK WHEN THE DIALOG IS RE-OPENED.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • To reproduce:
    - Create an MQ connection in Architecture School Logical View.
    - Create a test with a publish action and select the MQ
    connection.
    - Put some text such as "my value" into the queue name field.
    - Close and re-open the message action dialog.
    The value is lost.
    
    This prevents the use of tags containing spaces in this field.
    This is a regression issue compared with GH Tester 5.3.
    

Local fix

  • Workaround: Use values or tags without spaces.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users of Rational Integration Tester working with MQ     *
    * queue names containing blanks                                *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Spaces in the queue name field of a message action cause the *
    * field to be blank when the dialog is re-opened.              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to Rational Integration Tester v9.0.1 which includes *
    * a fix for this issue                                         *
    ****************************************************************
    

Problem conclusion

  • A fix for this issue was provided in version 9.0.1 of Rational
    Integration Tester.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI62695

  • Reported component name

    RATL INTEGRA TE

  • Reported component ID

    5725G79IT

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-05-18

  • Closed date

    2016-09-22

  • Last modified date

    2016-09-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL INTEGRA TE

  • Fixed component ID

    5725G79IT

Applicable component levels

  • R800 PSN

       UP

  • R801 PSN

       UP

  • R850 PSN

       UP

  • R851 PSN

       UP

  • R860 PSN

       UP

  • R870 PSN

       UP

  • R871 PSN

       UP

  • R900 PSN

       UP

  • R901 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"900","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
17 October 2021