Problem summary
**************************************************************** * USERS AFFECTED: All QMF for TSO/CICS V11.1 users. * **************************************************************** * PROBLEM DESCRIPTION: After applying the fix for PI58437, * * users can receive error message * * DSQ21492 'DSQEC_TRACE_MODULE is an * * invalid global variable name.' when * * issuing the SET GLOBAL command for * * DSQEC_TRACE_MODULE. Setting the global * * variable from the SHOW GLOBALS command * * prompt works successfully. * **************************************************************** * RECOMMENDATION: * **************************************************************** QMF 11.1 and lower supported a maximum of 17 character global variable name lengths through the SET GLOBAL command.
Problem conclusion
For QMF 11.1, the name of the global variable is changed from DSQEC_TRACE_MODULE to DSQEC_TRACE_MODUL.
Temporary fix
Comments
APAR Information
APAR number
PI59360
Reported component name
QMF-QUERY MGMT
Reported component ID
566872101
Reported release
B10
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-03-17
Closed date
2016-03-23
Last modified date
2016-04-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI36452
Modules/Macros
DSQCGVSI DSQCSETS
Fix information
Fixed component name
QMF-QUERY MGMT
Fixed component ID
566872101
Applicable component levels
RB10 PSY UI36452
UP16/03/24 P F603 Ø
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCWRCK","label":"QMF for TSO\/CICS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]