Stub Guard 'Record Doesn't Exist' does not work STEPS TO REPRODUCE: 1. Create a stub that has a guard condition 'Record Doesn't Exist' 2. Start the stub 3. Send an event to the stub that has a record that does not exist EXPECTED RESULTS: The stub should process the record ACTUAL RESULTS: The stub takes the configured Pass Through action of the stub WORKAROUND: Set the guard condition to 'None'. Put the Lookup Test Data flow in the Business Logic of the stub Add a Pass and Fail path Process the stub if the Fail condition is met
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All users of IBM Rational Integration Tester attempting to * * use the "Record Doesn't Exist" Guard condition in a stub * * event. * **************************************************************** * PROBLEM DESCRIPTION: * * The stub Guard condition "Record Doesn't Exist" does * * nothing. * * If this guard is used for an event and the record look-up * * fails, processing does not continue. The message is * * discarded or pass-through invoked depending on the stub * * configuration. The following event of the same type is * * ignored. * **************************************************************** * RECOMMENDATION: * * Upgrade to Rational Integration Tester v9.0 which includes a * * fix for this issue. * ****************************************************************
Problem conclusion
A fix for this issue was provided in version 9.0 of Rational Integration Tester.
Temporary fix
Comments
APAR Information
APAR number
PI56903
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
871
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-02-09
Closed date
2016-03-16
Last modified date
2016-03-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSN
UP
R870 PSN
UP
R871 PSN
UP
R900 PSN
UP
R900 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"871","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
16 October 2021