A fix is available
APAR status
Closed as program error.
Error description
When the COBOL runtime (SCEERUN) is in read-only memory (LPA/LINKLIST), a S0C4 can occur during a QSAM OPEN of a file that specifies RECFM=SPANNED & SAME RECORD AREA.
Local fix
Add the SCEERUN dataset to the STEPLIB in the program's execution JCL.
Problem summary
**************************************************************** * USERS AFFECTED: Enterprise COBOL 5.1 or 5.2 users running * * programs with QSAM spanned records and SAME * * RECORD AREA. * * * **************************************************************** * PROBLEM DESCRIPTION: Runtiem ABEND: When the COBOL runtime * * is in read-only memory (such as LPA), * * S0C4 ABEND occurs during QSAM OPEN of * * file with RECFM=SPANNED and SAME * * RECORD AREA(SRA). * * * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** Record buffer management for QSAM Spanned record, SRA was not REENTRANT, and caused an 0C4 ABEND. FIXCAT keyword: COB0501T/K COB0502T/K
Problem conclusion
The record buffer management code has been updated to be REENTRANT.
Temporary fix
Comments
APAR Information
APAR number
PI56013
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
790
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-01-25
Closed date
2016-02-11
Last modified date
2016-03-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI35305 UI35306 UI35307
Modules/Macros
IGZCEV4 IGZLLIBV IGZXAPI IGZXDMR IGZXD24 IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG IGZXPK2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
R7A0 PSY UI35305
UP16/02/19 P F602
R780 PSY UI35306
UP16/02/19 P F602
R790 PSY UI35307
UP16/02/19 P F602
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCVR7X","label":"Runtime"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
14 December 2020