IBM Support

PI54498: RDZ REAL-TIME SYNTAX CHECK RAISES INVALID ERROR FOR VALUE CLAUSE WITH QUOTES ON CONTINUATION LINE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In Rational Developer for System z - RDz - v9.1.1.2, real-time
    syntax check raises invalid error for VALUE clause with quotes
    on continuation line.
    
    For example, the following COBOL declarations:
    
    01 VALUEATTR001   PIC X(86)   value 'CODE0001 TEST SINGLE QUOTE'
    -          '' OPERATOR A "="'.
    
    01 STRING1 PIC X(86).
           88 VALUEATTR002         value 'CODE0001 TEST SINGLE
    QUOTE'
    -          ''OPERATOR A "=" '.
    
    gives errors:
    
    - "VALUE" expected instead of this input
    - "MissingLiteralCompletion" inserted to complete scope
    

Local fix

  • There is no known workaround at this time.
    

Problem summary

  • Real-time
    syntax check raises invalid error for VALUE clause with quotes
    on continuation line.
    
    For example, the following COBOL declarations:
    
    01 VALUEATTR001   PIC X(86)   value 'CODE0001 TEST SINGLE QUOTE'
    -          '' OPERATOR A "="'.
    
    01 STRING1 PIC X(86).
           88 VALUEATTR002         value 'CODE0001 TEST SINGLE
    QUOTE'
    -          ''OPERATOR A "=" '.
    
    gives errors:
    
    - "VALUE" expected instead of this input
    - "MissingLiteralCompletion" inserted to complete scope
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PI54498

  • Reported component name

    RATL DEV FOR SY

  • Reported component ID

    5724T0700

  • Reported release

    911

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-12-21

  • Closed date

    2016-02-26

  • Last modified date

    2016-02-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL DEV FOR SY

  • Fixed component ID

    5724T0700

Applicable component levels

  • R911 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSTRMM","label":"IBM Developer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"911","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: