A fix is available
APAR status
Closed as program error.
Error description
When a command is run from within a IBM Rational ClearCase dynamic view context and there are no vobrpc_server processes active then it will start one vobrpc_server process per VOB. This start up time and the time it takes the ClearCase client to contact it and gather information adds an extra overhead in transfer time of even non-ClearCase command outputs to the client. It is noted that the start up of a VOBrpc_server, the client contacting that server and the retrieval of information can take about 50ms per process. NOTE: the vobrpc_server processes are short lived so they require restarting after two minutes with no access WORKAROUND: Run a 'ls -l' every two minutes from a view context to keep the vobrpc_servers alive.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of ClearCase dynamic views. * **************************************************************** * PROBLEM DESCRIPTION: * * Delays executing calls in ClearCase due to vobrpc_server * * start-up. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
A fix is available in ClearCase versions 8.0.1.11 and 9.0
Temporary fix
Comments
APAR Information
APAR number
PI53364
Reported component name
CC&CC MSITE WIN
Reported component ID
5724G3300
Reported release
801
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-12-01
Closed date
2017-03-01
Last modified date
2017-03-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CC&CC MSITE WIN
Fixed component ID
5724G3300
Applicable component levels
R801 PSY
UP
R900 PSY
UP