Fixes are available
APAR status
Closed as program error.
Error description
You will see an error when using the UCD Blueprint Designer longer than 60 minutes after you are logged on. Once it happens the UCD Blueprint Designer becomes unusable until you log out and log back in. This is caused by the UCD Blueprint designer setting the token as valid when it has already expired in keystone.
Local fix
Increase the Keystone token expiration to 12 hours at the Keystone service.
Problem summary
**************************************************************** * USERS AFFECTED: * * All users * **************************************************************** * PROBLEM DESCRIPTION: * * You will see an error when using the UCD Blueprint Designer * * longer than 60 minutes after you are logged on * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
A fix is available in IBM UrbanCode Deploy 6.2.0.2
Temporary fix
Comments
APAR Information
APAR number
PI53118
Reported component name
UC DEPLOY
Reported component ID
5725M5400
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-11-25
Closed date
2015-12-19
Last modified date
2015-12-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
UC DEPLOY
Fixed component ID
5725M5400
Applicable component levels
R600 PSN
UP
R600 PSY
UP
R601 PSN
UP
R601 PSY
UP
R610 PSN
UP
R610 PSY
UP
R611 PSN
UP
R611 PSY
UP
R612 PSN
UP
R612 PSY
UP
R613 PSN
UP
R613 PSY
UP
R620 PSN
UP
R620 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS4GSP","label":"IBM UrbanCode Deploy"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
14 October 2021