Fixes are available
APAR status
Closed as program error.
Error description
HTTPS connections fail that previously worked with 8.6 versions of the product. The error seen in IBM Rational Integration Tester (RIT) is: java.net.SocketException: Connection reset WORKAROUND: Revert to earlier version of RIT.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All users of Rational Integration Tester working with HTTP * * transport * **************************************************************** * PROBLEM DESCRIPTION: * * HTTPS CONNECTION FAILS WITH JAVA.NET.SOCKETEXCEPTION: * * CONNECTION RESET * **************************************************************** * RECOMMENDATION: * * Upgrade to Rational Integration Tester v8.7.1..1 which * * includes a fix for this issue * **************************************************************** Tests using the HTTP transport send a 'Host' header in the request message that includes the port configured in the physical resource. If you do not want the port to be sent, clear the port field in the Physical view manually; in this case, the transport will connect to the default ports for HTTP or HTTPS (80 and 443 respectively).
Problem conclusion
A fix for this issue was provided in version 8.7.1.1 of Rational Integration Tester.
Temporary fix
Comments
APAR Information
APAR number
PI52057
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
800
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-11-06
Closed date
2015-12-29
Last modified date
2015-12-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSN
UP
R870 PSN
UP
R871 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
17 October 2021