IBM Support

PI50168: (WI 371322)BUILD DEFINITION PROPERTY SYNC IS NOT UPDATING THE PROPERTY VALUE FOR MULTIPLE PROPERTIES.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • IBM Rational Team Concert(RTC) build definition property "SYNC"
    for IBM Rational Build Forge (BF) is not updating the property
    value for multiple properties.
    
    Use Case:
    1. Define two environment variables (M1 and M2) setting their
    value to arbitrary values (for example 1 and 2) for a BF
    environment (myEnv)
    2. Create a BF Project that uses this environment
    3. In your BF Project, update the environment variables using
    the following step
    .set env myEnv "M1=10"
    .set env myEnv "M2=20"
    4. Create a BF build definition in RTC.
    5. Select your BF project
    6. Create build properties in RTC build definition  to
    correspond with your environment variables (M1 and M2)
    7. Add the following as your properties' description
    NORMAL, SET, SYNC - which should cause RTC to synchronize with
    Build Forge after a build finishes to pull the updated values
    8. Request a build using this RTC build definition
    
    What is expected:
    We would expect to see both M1 and M2 update with the new
    values, 10 and 20 respectively.
    
    
    What is observed:
    M1 updates to have a value of 10 but M2 shows the old value in
    RTC. In BF the value of M2 is updated to 20.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * ALL                                                          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * (WI 371322)BUILD DEFINITION PROPERTY SYNC IS NOT UPDATING    *
    * THE                                                          *
    * PROPERTY VALUE FOR MULTIPLE PROPERTIES.                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The issue was fixed in Build Forge 8.0.0.3 release
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI50168

  • Reported component name

    BUILD FORGE EE

  • Reported component ID

    5724S2701

  • Reported release

    712

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-10-08

  • Closed date

    2016-02-22

  • Last modified date

    2016-02-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    BUILD FORGE EE

  • Fixed component ID

    5724S2701

Applicable component levels

  • R712 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSB2MV","label":"Rational Build Forge"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1.2","Line of Business":{"code":"LOB45","label":"Automation"}}]