Error description
Rational Developer for System z - RDz - v9.1.0 Attempts to save a large Endevor cobol program that was opened using the Enhanced Edit may result in an ABEND 0C4 in CRASERV. Below are details of the abend: In one case the abend occurred in: 1 CEEHDSP +0000447E CEEPLPKA CEEHDSP UI19379 Call 2 setupCustomReturnKey +00000180 CRASERV Exception 3 serv_putMember +000006FC CRASERV Call In another case it occurred in: 1 CEEHDSP +00004A4C CEEPLPKA CEEHDSP UI90017 Call 2 allocateKeyVal +000001D2 CRASERV Exception 3 setupCustomReturnKeys +0000021C CRASERV Call
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: 01.RDz users who access the CA Endevor * * repository using the IBM supplied * * RDz Endevor RAM. * **************************************************************** * PROBLEM DESCRIPTION: 01.RDz Attempts to save large program * * opened using CARMA Enhanced Editor * * result in Abend0C4. * **************************************************************** * RECOMMENDATION: * **************************************************************** 01.The error happens when the internal return code is not set by the RDz Endevor RAM when sending the response to the RDz client.
Problem conclusion
01.The CARMA Endevor RAM is updated to ensure that the internal return code is set each time.
Temporary fix
Comments
APAR Information
APAR number
PI49872
Reported component name
RATL DEV FOR SY
Reported component ID
5724T0700
Reported release
910
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-10-02
Closed date
2015-10-16
Last modified date
2015-10-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI32110
Modules/Macros
CRARNDVR
Fix information
Fixed component name
RD/Z HOST
Fixed component ID
5724T0723
Applicable component levels
R910 PSY UI32110
UP15/10/21 I 1000
Fix is available