APAR status
Closed as program error.
Error description
STEPS TO REPRODUCE : 1) Setup RIT integration to Jenkins 2) Create Ant script (or you can simply generate your Ant script from RIT GUI) against a test script and make sure to enable JUnit reporting 3) Run your Ant script through Jenkins integration to RIT EXPECTED RESULTS : JUnit report generated for each of the Ant script execution ACTUAL RESULTS : No JUnit report gets generated for Ant scripts running test cases
Local fix
Workaround for now is to run test suites through your Ant script rather than test cases.
Problem summary
**************************************************************** * USERS AFFECTED: * * All users of IBM Rational Integration Tester (RIT) * * attempting to create JUnit results from tests run via Ant. * **************************************************************** * PROBLEM DESCRIPTION: * * When running test sequences via an Ant script, JUnit tests * * were not created even if the configuration to create them * * was correctly set. * **************************************************************** * RECOMMENDATION: * * Update to version 8.7.1.1 or newer of IBM Rational * * Integration Tester to resolve this problem. * ****************************************************************
Problem conclusion
Version 8.7.1.1 of IBM Rational Integration Tester contains the fix for this problem.
Temporary fix
Comments
APAR Information
APAR number
PI49234
Reported component name
RATL TEST WORKB
Reported component ID
5725G7900
Reported release
870
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-09-23
Closed date
2016-03-29
Last modified date
2016-03-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL TEST WORKB
Fixed component ID
5725G7900
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSN
UP
R870 PSN
UP
R871 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"IBM Rational Test Workbench"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.7","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]