Error description

  • The compiler is generating and leaving behind un-necessary tmp
    files without deleting them after its use.
    
    $ date; cob2 test.cbl; ls -l /tmp/SYS*
    Wed Mar  4 15:33:05 EST 2015
    IGYSI5013-U   An error occurred while attempting to open file
    "/gsa/tlbgsa-h1/05/bkanneth/web/private/70791/test.cbl".: No
    such file or directory
    The compiler terminated abnormally
    -rw-------    1 bkanneth staff             0 Mar 04 15:33
    /tmp/SYS0y-Xae7a
    -rw-------    1 hosts/dc staff             0 May 03 2013
    /tmp/SYS0y_Gafaa
    $
    

Local fix

  • Manually clean the tmp files.
    

Problem summary

  • USERS AFFECTED:
    COBOL for AIX users compiling any files that may issue an
    unexpected compiler abend may be affected by this issue.
    
    PROBLEM DESCRIPTION:
    There was a certain path within the compiler where temporary
    files were being generated, but not deleted after its use.
    

Problem conclusion

  • The temporary files are now being deleted after its use.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI48347

  • Reported component name

    COBOL FOR AIX

  • Reported component ID

    5724Z8700

  • Reported release

    411

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-09-08

  • Closed date

    2015-09-08

  • Last modified date

    2015-09-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PI55300

Fix information

  • Fixed component name

    COBOL FOR AIX

  • Fixed component ID

    5724Z8700

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SGM","label":"COBOL for AIX"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"411","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
15 October 2021