A fix is available
APAR status
Closed as program error.
Error description
Message CSQE112E: CSQERCF2 Unable to recover structure xxxxxxxx, failed to read required logs issued during recovery. However, the necessary logs are available for recovery.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of WebSphere MQ for z/OS Version 8 * * Release 0 Modification 0. * **************************************************************** * PROBLEM DESCRIPTION: Message CSQE112E issued incorrectly. * **************************************************************** * RECOMMENDATION: * **************************************************************** During coupling facility structure recovery persistent messages are recovered from the active log backup data set by module csqercf2. However the recovery fails with message CSQE022E because the coupling facility structure is not large enough to contain all the messages in the backup. Although CSQE022E is issued validly, it is followed by an invalid message CSQE112E, reporting that the recovery failed because the required logs could not be read. The necessary logs are available for recovery. A similar problem can occur when module csqerrpb recovers persistent messages from the logs. Additional keywords: fReadingLogs RTA.fReadingLogs critprr
Problem conclusion
Module csqercf2 is updated so that it no longer issues the invalid message CSQE112E reported during coupling facility structure recovery from the backup. A similar change is made to module csqerrpb for structure recovery from the logs. 000Y CSQERCF2 CSQERRPB
Temporary fix
Comments
APAR Information
APAR number
PI48216
Reported component name
WMQ Z/OS 8
Reported component ID
5655W9700
Reported release
000
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-09-04
Closed date
2016-03-23
Last modified date
2016-06-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI36445
Modules/Macros
CSQERCF2 CSQERRPB
Fix information
Fixed component name
WMQ Z/OS 8
Fixed component ID
5655W9700
Applicable component levels
R000 PSY UI36445
UP16/05/04 P F605
Fix is available