Fixes are available
Rational ClearCase Fix Pack 11 (8.0.1.11) for 8.0.1
Rational ClearCase Fix Pack 1 (9.0.0.1) for 9.0
Rational ClearCase Fix Pack 12 (8.0.1.12) for 8.0.1
Rational ClearCase Fix Pack 2 (9.0.0.2) for 9.0
Rational ClearCase Fix Pack 13 (8.0.1.13) for 8.0.1
Rational ClearCase Fix Pack 3 (9.0.0.3) for 9.0
Rational ClearCase Fix Pack 14 (8.0.1.14) for 8.0.1
Rational ClearCase Fix Pack 4 (9.0.0.4) for 9.0
Rational ClearCase Fix Pack 15 (8.0.1.15) for 8.0.1
Rational ClearCase Fix Pack 5 (9.0.0.5) for 9.0
Rational ClearCase Fix Pack 6 (9.0.0.6) for 9.0
Rational ClearCase Fix Pack 16 (8.0.1.16) for 8.0.1
Rational ClearCase Fix Pack 17 (8.0.1.17) for 8.0.1
Rational ClearCase Fix Pack 18 (8.0.1.18) for 8.0.1
Rational ClearCase Fix Pack 19 (8.0.1.19) for 8.0.1
Rational ClearCase Fix Pack 20 (8.0.1.20) for 8.0.1
Rational ClearCase Fix Pack 21 (8.0.1.21) for 8.0.1
Rational ClearCase Fix Pack 22 (8.0.1.22) for 8.0.1
Rational ClearCase Fix Pack 23 (8.0.1.23) for 8.0.1
Rational ClearCase Fix Pack 24 (8.0.1.24) for 8.0.1
Rational ClearCase Fix Pack 25 (8.0.1.25) for 8.0.1
APAR status
Closed as program error.
Error description
In IBM Rational ClearCase version 8.0.1.8 the "Finish" button is greyed out when creating an integration view from the "join project" dialogue in ClearTeamExplorer (CTE). Reproduction steps: 1) Start ClearTeamExplorer 2) Right-Click on My Views->Join Project 3) Select an integration stream or project (if it's the default integration stream for the project) 3) Un-check "Set up a Development Stream" 4) Under "Create an Integration View, select "Dynamic" 5) After clicking "Next", I can't go further because the "Finish" button is grayed WORKAROUND: workaround 1: Check "Set up a Development Stream" and choose dynamic view then un-check "Set up a Development Stream" alternatively: Browse to the stream in the Navigator, right-click, select Create View or Click the 'Create View' button on the toolbar; In the Create View dialog, check the "create a view on an existing UCM stream" checkbox
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of the Rational ClearTeam Explorer join project * * feature. * **************************************************************** * PROBLEM DESCRIPTION: * * In IBM Rational ClearCase, when creating an integration view * * from the "join project" dialogue in ClearTeam Explorer, the * * "Finish" button is greyed out. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
A fix is available in ClearCase versions 8.0.1.11 and 9.0.0.1
Temporary fix
Comments
APAR Information
APAR number
PI48197
Reported component name
CLEARCASE WIN
Reported component ID
5724G2900
Reported release
801
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-09-04
Closed date
2016-05-31
Last modified date
2016-05-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CLEARCASE WIN
Fixed component ID
5724G2900
Applicable component levels
R801 PSY
UP
R900 PSY
UP
Document Information
Modified date:
15 October 2021