  • Closed as program error.

Error description

  • The EGL variables that contain variable length SQL variables are
    defined as PIC 9(4) COMP-4. When using COBOL compiler option
    TRUNC(STD) this causes a maximum length of 9999, but be defining
    the PIC field as COMP-5 instead, the maximum length would
    increase to 32767.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users on zSystem that have cobol compiler option trunc(std)  *
    * and are using sql variable length fields that are greater    *
    * than 9999 bytes in size.                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * The trunc(std) compiler option affects comp-4 fields. EGL    *
    * was defining the variable length for the sql field as        *
    * comp-4, which would then only allow a max size of 9999. The  *
    * software has been changed for the 49 level variable length   *
    * only, to be comp-5, which means that no matter what trunc    *
    * compiler option is used, the max size increases to 32767.    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The software was updated.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI44384

  • Reported component name

    RATL BUS DEV

  • Reported component ID

    5724S5000

  • Reported release

    911

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-07-06

  • Closed date

    2016-04-05

  • Last modified date

    2016-04-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL BUS DEV

  • Fixed component ID

    5724S5000

Applicable component levels

  • R901 PSY

       UP

  • R911 PSY

       UP

  • R950 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.1.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]