IBM Support

PI43402: ABEND0C4 RC00000010 AT DSNXERD OFFSET4A42 WHEN THE CICS APPLICATION CALLED A STORED PROCEDURE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A CICS application called a stored procedure and a SQLCODE -904
    was issued when running the stored procedure. After exiting
    from the stored procedure, DB2 detected a SQLCODE -905 was
    issued so DSNXERD tried to notify WLM which executed the stored
    procedure of the earlier SQLCODE -904. During this notify
    process, the thread failed with ABEND0C4 RC00000010 at DSNXERD
    OFFSET4A42.
    
    Additional keywords to be used for searching:
    SQLSP SQLSTOREDPROC SQLCODE904 SQLCODE905
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All DB2 10 and 11 for zOS users who call     *
    *                 DB2 stored procedures through CICS           *
    *                 applications.                                *
    ****************************************************************
    * PROBLEM DESCRIPTION: A CICS application called a stored      *
    *                      procedure and the stored procedure      *
    *                      issued SQLCODE -904. After returning    *
    *                      to the CICS application, another DB2    *
    *                      error SQLCODE was issued.               *
    *                      Under this condition, an abend such as  *
    *                                                              *
    *                      ABEND0C4 RC00000010 DSNXERD OFFSET4A42  *
    *                                                              *
    *                      can occur.                              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    After the second SQL error was raised, DB2 tried to retrieve
    a CICS token in order to inform the WLM address space that an
    SQLCODE -904 had been raised earlier in the stored procedure.
    
    The instructions used to retrieve the the CICS token were not
    set up correctly and resulted in the abend.
    

Problem conclusion

  • DB2 has corrected the instructions to retrieve the CICS token
    so that the abend does not occur.
    
    Additional keywords to be used for searching:
    SQLSP SQLSTOREDPROC SQLCODE904
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI43402

  • Reported component name

    DB2 OS/390 & Z/

  • Reported component ID

    5740XYR00

  • Reported release

    A10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-06-23

  • Closed date

    2015-08-25

  • Last modified date

    2015-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI30517 UI30518

Modules/Macros

  • DSNXERD
    

Fix information

  • Fixed component name

    DB2 OS/390 & Z/

  • Fixed component ID

    5740XYR00

Applicable component levels

  • RA10 PSY UI30517

       UP15/09/10 P F509

  • RB10 PSY UI30518

       UP15/09/10 P F509

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEPEK","label":"Db2 for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: