Closed as program error.
Error description
Problem reproduced in Synergy 7.2.1 (tested with 7.2.1.3.01) Top-1 and Sub-1 are respectively copy based absolute project and subproject in integrate state with work-area maintained. 1) Synergy 7.1 with Classic client. Top-1 and Sub-1 are integrate Set the build manager role Delete workareas of Top-1 and Sub-1 Check out a prep project Top-2, from Top-1 (without subprojects) The workarea for Top-2 is created. In Top-2, select Sub-1 subproject and Sync it => The subproject Sub-1 is synced. => The behavior is the same for a new working top project. 2) Synergy 7.1 client GUI in Web mode: -Delete the workareas of Top-1 and Sub-1 -Do a Copy project on Top-1 (without subprojects) to create a new prep project Top-2 The workarea for Top-2 is created. -In Top-2, select the subproject Sub-1 and click on Sync Workarea/Members and Subprojects => The subproject Sub-1 is NOT synced The following error is reported: ## Static work area could not be updated. Unable to update static work area for Sub-1 under Top-2, subproject is not relative. ## => This problem/behavior is the same for a new working top project. Expected Result: => The subproject Sub-1 should be synced. 3) Synergy 7.2.1 client GUI: -Delete workareas of Top-1 and Sub-1 -Do a Copy project on Top-1 (without subprojects) to create a new prep project Top-2 The workarea for Top-2 is created. -In Top-2, select the subproject Sub-1 and click on Sync Workarea/Members and Subprojects => The subproject Sub-1 is NOT synced The following error is reported: ## CRCCM0170: The static work area could not be updated. Unable to update static work area for Sub-1 under Top-2, subproject is not relative. ## => This problem/behavior is the same for a new working top project. Expected Result: => The subproject Sub-1 should be synced.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Build managers working on static subprojects with absolute * * work area path * **************************************************************** * PROBLEM DESCRIPTION: * * Top-1 and Sub-1 are respectively copy based absolute project * * and * * subproject in integrate state with work-area maintained. * * Top-1 and Sub-1 are integrate * * Delete workareas of Top-1 and Sub-1 * * Check out a prep project Top-2, from Top-1 (without * * subprojects) * * The workarea for Top-2 is created. * * -In Top-2, select the subproject Sub-1 and click on Sync * * Workarea/Members and Subprojects * * * * => The subproject Sub-1 is NOT synced * * * * The following error is reported: * * ## * * CRCCM0170: The static work area could not be updated. * * Unable to update static work area for Sub-1 under Top-2, * * subproject is not relative. * * ## * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Fixed in Rational Synergy 7.2.1.4 iFix01
Temporary fix
Comments
APAR Information
APAR number
PI41489
Reported component name
TLOGIC SYNERGY
Reported component ID
5724V66SN
Reported release
721
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-05-20
Closed date
2015-12-10
Last modified date
2015-12-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC SYNERGY
Fixed component ID
5724V66SN
Applicable component levels
R721 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSRNYG","label":"Rational Synergy"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"721","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
14 October 2021