IBM Support

PI41489: STATIC SUBPROJECTS, WITH ABSOLUTE WORKAREA, CANNOT BE RE-SYNCED IN THE GUI.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Problem reproduced in Synergy 7.2.1 (tested with 7.2.1.3.01)
    
    Top-1 and Sub-1 are respectively copy based absolute project and
    subproject in integrate state with work-area maintained.
    
    1) Synergy 7.1 with Classic client.
    Top-1 and Sub-1 are integrate
    Set the build manager role
    
    Delete workareas of Top-1 and Sub-1
    Check out a prep project Top-2, from Top-1 (without subprojects)
    The workarea for Top-2 is created.
    In Top-2, select Sub-1 subproject and Sync it
    => The subproject Sub-1 is synced.
    
    => The behavior is the same for a new working top project.
    
    
    2) Synergy 7.1 client GUI in Web mode:
    -Delete the workareas of Top-1 and Sub-1
    -Do a Copy project on Top-1 (without subprojects) to create a
    new prep project Top-2
    The workarea for Top-2 is created.
    -In Top-2, select the subproject Sub-1 and click on Sync
    Workarea/Members and Subprojects
    
    => The subproject Sub-1 is NOT synced
    
    The following error is reported:
    ##
    Static work area could not be updated.
    Unable to update static work area for Sub-1 under Top-2,
    subproject is not relative.
    ##
    
    => This problem/behavior is the same for a new working top
    project.
    
    Expected Result:
    => The subproject Sub-1 should be synced.
    
    
    3) Synergy 7.2.1 client GUI:
    -Delete workareas of Top-1 and Sub-1
    -Do a Copy project on Top-1 (without subprojects) to create a
    new prep project Top-2
    The workarea for Top-2 is created.
    -In Top-2, select the subproject Sub-1 and click on Sync
    Workarea/Members and Subprojects
    
    => The subproject Sub-1 is NOT synced
    
    The following error is reported:
    ##
    CRCCM0170: The static work area could not be updated.
    Unable to update static work area for Sub-1 under Top-2,
    subproject is not relative.
    ##
    
    => This problem/behavior is the same for a new working top
    project.
    
    Expected Result:
    => The subproject Sub-1 should be synced.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Build managers working on static subprojects with absolute   *
    * work area path                                               *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Top-1 and Sub-1 are respectively copy based absolute project *
    * and                                                          *
    * subproject in integrate state with work-area maintained.     *
    * Top-1 and Sub-1 are integrate                                *
    * Delete workareas of Top-1 and Sub-1                          *
    * Check out a prep project Top-2, from Top-1 (without          *
    * subprojects)                                                 *
    * The workarea for Top-2 is created.                           *
    * -In Top-2, select the subproject Sub-1 and click on Sync     *
    * Workarea/Members and Subprojects                             *
    *                                                              *
    * => The subproject Sub-1 is NOT synced                        *
    *                                                              *
    * The following error is reported:                             *
    * ##                                                           *
    * CRCCM0170: The static work area could not be updated.        *
    * Unable to update static work area for Sub-1 under Top-2,     *
    * subproject is not relative.                                  *
    * ##                                                           *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Fixed in Rational Synergy 7.2.1.4 iFix01
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI41489

  • Reported component name

    TLOGIC SYNERGY

  • Reported component ID

    5724V66SN

  • Reported release

    721

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-05-20

  • Closed date

    2015-12-10

  • Last modified date

    2015-12-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC SYNERGY

  • Fixed component ID

    5724V66SN

Applicable component levels

  • R721 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSRNYG","label":"Rational Synergy"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"721","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: