Fixes are available
APAR status
Closed as program error.
Error description
When an application attempts to connects to a Worklight/MobileFirst server but does not have a connection to the internet, the application crashes with the following exception E/ActivityThread(9222): Activity [activity name] has leaked IntentReceiver com.worklight.androidgap.plugin.Push$4@42bfe8a8 that was originally registered here. Are you missing a call to unregisterReceiver()? The issue lies in Push Hybrid not providing the senderIds correctly to the GCM service when there is a retry to connect to GCM server after the first SERVICE_NOT_AVAILABLE error.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * The users of MobileFirst Platform Android Client embedded in * * an application and has network issues during the startup * **************************************************************** * PROBLEM DESCRIPTION: * * The issue occurs with the retry logic code which needs to * * keep attempting to connect to GCM server with a exponential * * backoff. The retry logic only kicks in after the first * * failure to connect to GCM. * **************************************************************** * RECOMMENDATION: * * - * ****************************************************************
Problem conclusion
The fix ensures that the retry logic is correctly used from the gcm client. There will be a exponential backoff when attempting to connect to Google Cloud messaging server.
Temporary fix
Comments
APAR Information
APAR number
PI39829
Reported component name
WL/MFPF CONSUME
Reported component ID
5725I4301
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-04-24
Closed date
2015-07-01
Last modified date
2015-07-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WL/MFPF CONSUME
Fixed component ID
5725I4301
Applicable component levels
R630 PSY
UP
R700 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB45","label":"Automation"}}]