PI38978: ERROR BUILDING NATIVE API APPLICATION: "MANDATORY PLATFORMVERSION"

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The following error occurs when using Ant script to build a
    native API application:
    
    FWLST2021E: Mandatory platformVersion parameter is missing from
    application-descriptor.xml
    
    The platformVersion parameter is set in
    application-descriptor.xml with 6.1.0.01.20140821-0406.
    
    Replacing the '-' with '.' resolves the issue.
    
    The platformVersion parameter should accept the '-' character.
    

Local fix

  • Replace the '-' with '.' in the platformVersion parameter
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Customers that build Worklight application using Worklight   *
    * ant builder                                                  *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * If using Worklight ant builder there is no validation of     *
    * application-descriptor.xml file thus if it is corrupted the  *
    * exception is thrown. The exception contains version number   *
    * of platform. There was a defect parsing that version number. *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * -                                                            *
    ****************************************************************
    

Problem conclusion

  • Code has been fixed to parse platform version number properly
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI38978

  • Reported component name

    WL/MFPF ENTERPR

  • Reported component ID

    5725I4300

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-04-13

  • Closed date

    2015-05-07

  • Last modified date

    2015-05-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WL/MFPF ENTERPR

  • Fixed component ID

    5725I4300

Applicable component levels

  • R610 PSY

       UP

  • R620 PSY

       UP

  • R630 PSY

       UP

  • R700 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
15 October 2021