A fix is available
APAR status
Closed as program error.
Error description
When specifying JSON object(s) as the "arguments" parameter value to the "mfp adapter call" command, an "Unexpected token" syntax error is displayed. For example, an "Unexpected token %" syntax error will result when specifying the JSON object {"a":"b"} as the "arguments" parameter value.
Local fix
Specify the JSON Object parameters, providing a String, Number, Boolean or Array of Strings, Numbers, Booleans, and/or sub-Arrays. For example, instead of specifying {"a":"b"}, specify ["a", "b"].
Problem summary
**************************************************************** * USERS AFFECTED: * * MobileFirst Foundation Platform developers who develop, test * * and verify MobileFirst adapters. * **************************************************************** * PROBLEM DESCRIPTION: * * When specifying JSON object(s) as the "arguments" parameter * * value of the the "mfp adapter call" command, and * * 'Unexpected token" syntax error is displayed. For example, * * an "Unexpected token %" syntax error will result when * * specifying the JSON object {"a":"b"} as the "arguments" * * parameter value. * **************************************************************** * RECOMMENDATION: * * - * ****************************************************************
Problem conclusion
The code was changed to URL-encode the arguments value after the value is parsed.
Temporary fix
Comments
APAR Information
APAR number
PI37818
Reported component name
WL/MFPF CONSUME
Reported component ID
5725I4301
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-03-25
Closed date
2015-04-06
Last modified date
2015-04-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WL/MFPF CONSUME
Fixed component ID
5725I4301
Applicable component levels
R700 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"700","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
17 October 2021