Error description
Rational Developer for System z - RDz - v9.1.1 editors cannot find copybooks referenced by a -INC statement before column 7. Steps to reproduce 1- edit a COBOL program with the following statements in COBOL editor or LPEX: IDENTIFICATION DIVISION. PROGRAM-ID. HELLO. DATA DIVISION. WORKING-STORAGE SECTION. -INC CPYINC1 PROCEDURE DIVISION. END PROGRAM HELLO. 2- error ""ERROR_TOKEN" unexpected tokens ignored" is marked on the line of -INC
Local fix
Move the "-inc" statement between columns 7 and 72
Problem summary
Editors cannot find copybooks referenced by a -INC statement before column 7. Steps to reproduce 1- edit a COBOL program with the following statements in COBOL editor or LPEX: IDENTIFICATION DIVISION. PROGRAM-ID. HELLO. DATA DIVISION. WORKING-STORAGE SECTION. -INC CPYINC1 PROCEDURE DIVISION. END PROGRAM HELLO. 2- error ""ERROR_TOKEN" unexpected tokens ignored" is marked on the line of -INC
Problem conclusion
Modified the COBOL parser to accept the -INC statement before column 7. The problem listed in this APAR has been resolved with IBM Rational Developer for System z V9.1.1.1 Fix Pack which is available from the Recommended Fixes support download page: http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
Temporary fix
Comments
APAR Information
APAR number
PI33855
Reported component name
RATL DEV FOR SY
Reported component ID
5724T0700
Reported release
911
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-01-30
Closed date
2015-03-24
Last modified date
2015-03-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL DEV FOR SY
Fixed component ID
5724T0700
Applicable component levels
R911 PSY
UP
Document Information
Modified date:
14 October 2021