Error description

  • REORG in DSNTIJEN ends with 00C90101 in DSNIDBIN with
    ERQUAL5005.
    Customer had altered REORG in DSNTIJEN to use the incorrect
    SHRLEVEL in an INSTALL / MIGRATE case.
    

Local fix

  • Do NOT alter generated REORG parameters in DSNTIJEN.  Follow
    directions in DB2 INSTALLATION AND
     MIGRATION documentation.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All DB2 10 for z/OS and DB2 11 for z/OS      *
    *                 customers running the DSNTIJEN job.          *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND04E RC00C90101 DSNIDBIN:5005       *
    *                      during DSNTIJEN job step ENFM0027       *
    *                      when executing the DB2 10 for z/OS      *
    *                      ENFM process.                           *
    ****************************************************************
    * RECOMMENDATION: Apply corrective PTF when available          *
    ****************************************************************
    The ABEND04E RC00C90101 in DSNIDBIN ERQUAL5005 happened during
    DSNTIJEN job REORG processing because the REORG SHRLEVEL
    keyword parameter was modified to a value that is incompatible
    with ENFM REORG processing.
    
    ENFM processing REORGs in the DSNTIJEN job (noted by the
    CONVERTV10 or CONVERTV11 keywords) require specific SHRLEVEL
    values for processing. If the SHRLEVEL keyword value is changed
    to an incompatible value then the ENFM processing REORGs will
    fail unpredictably.
    
    Additional keywords:
     DB2MIGV10/K DB2MIGV11/K ABEND04E
     RC00C90101 ERQUAL5005 MSGDSNU071I
    

Problem conclusion

  • DB2 code has been changed so that an incompatible REORG SHRLEVEL
    keyword value cannot be specified for an ENFM REORG (job
    DSNTIJEN with the CONVERTV10 or CONVERTV11 keyword).
    
    If an invalid ENFM REORG SHRLEVEL value is now specified then
    message DSNU071I will be issued and the DSNTIJEN job will stop
    with RC=8. The SHRLEVEL value noted in MSGDSNU071I will indicate
    the required SHRLEVEL value for the ENFM REORG being attempted.
    
    In DB2 10 for z/OS all of the DSNTIJEN ENFM REORGs are
    'SHRLEVEL REFERENCE'. In DB2 11 for z/OS there are three
    DSNTIJEN ENFMs that are 'SHRLEVEL REFERENCE' (SYSCOPY, SYSRTSTS,
    and SYSSTR) and three that are 'SHRLEVEL CHANGE' (SYSLGRNX,
    SYSTSIXS, and SYSTSTAB).
    
    Here are a couple examples of the DSNU071I messages that might
    be displayed if an invalid SHRLEVEL value is encountered in the
    DSNTIJEN job during ENFM processing:
    
      DSNU071I  @ 029 12:13:47.76 DSNURFIT - KEYWORD 'CONVERTV10'
                REQUIRES KEYWORD 'SHRLEVEL REFERENCE'
    
      DSNU071I  @ 029 12:13:47.76 DSNURFIT - KEYWORD 'CONVERTV11'
                REQUIRES KEYWORD 'SHRLEVEL CHANGE'
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI33533

  • Reported component name

    DB2 OS/390 & Z/

  • Reported component ID

    5740XYR00

  • Reported release

    A10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-01-27

  • Closed date

    2015-02-12

  • Last modified date

    2015-03-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI25126 UI25127

Modules/Macros

  •    DSNURFIT
    

Fix information

  • Fixed component name

    DB2 OS/390 & Z/

  • Fixed component ID

    5740XYR00

Applicable component levels

  • RA10 PSY UI25126

       UP15/02/28 P F502

  • RB10 PSY UI25127

       UP15/02/28 P F502

Fix is available