IBM Support

PI33176: APPCENTER : OUTOFMEMORY OR TIMEOUT CAN OCCUR WHEN THE METHOD 'REMOVEUNUSEDONETIMEURLS' EXECUTES

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In the application server log OutOfMemory or Timeout can occur
    when the method 'removeUnusedOneTimeUrls' executes due to a huge
    number of records in the ONETIMEURL table.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * AppCenter Mobile clients                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * In the application server log OutOfMemory or Timeout can     *
    * occur when the method 'removeUnusedOneTimeUrls' executes due *
    * to a huge number of records in the ONETIMEURL table.         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * -                                                            *
    ****************************************************************
    

Problem conclusion

  • Replaces OneTimeUrl mechanism : encryption with hash and DB
    recording is replaced by symmetric encryption without DB.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI33176

  • Reported component name

    WL/MFPF CONSUME

  • Reported component ID

    5725I4301

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-01-21

  • Closed date

    2015-02-02

  • Last modified date

    2015-02-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WL/MFPF CONSUME

  • Fixed component ID

    5725I4301

Applicable component levels

  • R620 PSY

       UP

  • R630 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB45","label":"Automation"}}]