Fixes are available
Rational Software Architect Designer 9.5.0
Rational Software Architect Designer for WebSphere Software Fix Pack 1 (9.5.0.1) for 9.5.0
Rational Software Architect Designer for WebSphere Software 9.5.0
Rational Software Architect Designer Fix Pack 2 (9.5.0.2) for 9.5.0
Rational Software Architect Designer for WebSphere Software Fix Pack 2 (9.5.0.2) for 9.5.0
Rational Software Architect Designer for WebSphere Software Fix Pack 3 (9.5.0.3) for 9.5.0
Rational Software Architect Designer Fix Pack 3 (9.5.0.3) for 9.5.0
APAR status
Closed as program error.
Error description
In IBM Rational Software Architect (RSA), if you attempt to copy and paste cells from a Microsoft excel document into the documentation field of an UML element, nothing happens. Inspecting the workspace .log, you see the error: -- java.lang.IllegalArgumentException: TableCells can only be added to FlowTables at com.ibm.xtools.richtext.gef.internal.figures.TableCell.checkVali dParent(TableCell.java:23) at com.ibm.xtools.richtext.gef.internal.figures.FlowFigure.setParen t(FlowFigure.java:207) at org.eclipse.draw2d.Figure.add(Figure.java:155) --- Description of problem/Step to reproduce with Rational Software Architect v9.1 and 9.1.1 1. Create a new UML model 2. Add a new Component to the model 3. Open an excel sheet where you have entered data. 4. Select and copy a cell containing some text (you can use CTRL+C) 5. Go to the component documentation tab 6. Paste the content of the cell you copied in step 4 (you can use CTRL+V) Expected Result: The cell information is copied to the documentation of the component Actual Result: Nothing happens and you get the error 'Java.lang.IllegalArgumentException: TableCells can only be added to FlowTables' thrown in the log. Local Fix: WORKAROUND: 1- Choose to 'Paste as text' using the right click option of the documentation rich text documentation field. 2. Copy the text of the cell from the Formula bar in excel before pasting it in the RSA rich text documentation field.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of Rational Software Architect, Rational Software * * Architect for Websphere Software, Rational Software * * Architect Realtime Edition who are migrating from 7.5.x * * version to any of 8.x.x (upto 9.1.x) will get affected. * **************************************************************** * PROBLEM DESCRIPTION: * * Copy and Paste from Microsoft excel table into the * * documentation sections of UML elements was throwing error * * and nothing was pasted. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
"Copy and Paste from Microsoft excel table into the documentation sections of UML elements is now supported. For additional information about the changes here, please see the tech note: http://www-01.ibm.com/support/docview.wss?uid=swg21966116 "
Temporary fix
Comments
APAR Information
APAR number
PI30923
Reported component name
SW ARCHITECT WI
Reported component ID
5724I7001
Reported release
910
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-12-04
Closed date
2015-09-18
Last modified date
2015-09-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SW ARCHITECT WI
Fixed component ID
5724I7001
Applicable component levels
R804 PSY
UP
R850 PSY
UP
R851 PSY
UP
R900 PSY
UP
R910 PSY
UP
R911 PSY
UP
R912 PSY
UP
Document Information
Modified date:
16 October 2021