Fixes are available
Rational Integration Tester Fix Pack 3 (8.6.0.3) for 8.6
Rational Performance Test Server Fix Pack 3 (8.6.0.3) for 8.6
Rational Test Virtualization Server Fix Pack 3 (8.6.0.3) for 8.6
Rational Integration Tester Fix Pack 4 (8.6.0.4) for 8.6
Rational Performance Test Server Fix Pack 4 (8.6.0.4) for 8.6
Rational Test Virtualization Server Fix Pack 4 (8.6.0.4) for 8.6
APAR status
Closed as program error.
Error description
At the end of a performance test you see the following errors: [27/11/2014 10:05:35.258] **** STOPPING PROBES **** [27/11/2014 10:05:35.258] Stopping: http://localhost:4476 [27/11/2014 10:05:35.268] Waiting for all probes to stop... [27/11/2014 10:05:35.271] Waiting for probes on http://localhost:4476 to exit... [27/11/2014 10:05:35.339] [Error] Probe ERROR: http://localhost:4476 - Failed to insert datasource message in DB - com.ghc.ghviewer.api.impl.DefaultDatasourceData@521279d4 [27/11/2014 10:05:35.342] [Error] [CRRIT8591E] Not all probes were reported exited within 30 seconds. [27/11/2014 10:05:35.343] [Error] [CRRIT8581E] http://localhost:4476 did not receive exit notification within 30 seconds. [27/11/2014 10:05:35.782] Summarizing performance test data... [27/11/2014 10:05:35.893] Summarizing performance test data completed [27/11/2014 10:05:35.893] [Error] [CRRIT8531E] <test name>: exited due to error ============================== The test has successfully run and data has been stored in the Project Database.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All users of Rational Performance Test Server * **************************************************************** * PROBLEM DESCRIPTION: * * After running a Performance Test that has used probes a user * * sees a set of (spurious) error logs in the RIT console from * * the end of the test. These errors are similar to: * * * * [27/11/2014 10:05:35.339] [Error] Probe ERROR: * * http://localhost:4476 - Failed to insert datasource message * * in DB - * * com.ghc.ghviewer.api.impl.DefaultDatasourceData@521279d4 * * [27/11/2014 10:05:35.342] [Error] [CRRIT8591E] Not all * * probes were reported exited within 30 seconds. * * [27/11/2014 10:05:35.343] [Error] [CRRIT8581E] * * http://localhost:4476 did not receive exit notification * * within 30 seconds. * * [27/11/2014 10:05:35.782] Summarizing performance test * * data... * * [27/11/2014 10:05:35.893] Summarizing performance test data * * completed * * [27/11/2014 10:05:35.893] [Error] [CRRIT8531E] * * calculator/Add/Perf: exited due to error * * * * These errors do not affect the test (as they are logged * * during shut down / clean up) but are distracting for the * * users. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
This problem was fixed in version 8.6.0.3 of Rational Integration Tester and the error logs no longer appear.
Temporary fix
Comments
APAR Information
APAR number
PI30485
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
860
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-11-27
Closed date
2015-01-02
Last modified date
2015-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.6","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
16 October 2021