Fixes are available
Rational Build Forge Fix Pack 3 (8.0.0.3) for 8.0
Rational Build Forge Fix Pack 4 (8.0.0.4) for 8.0
Rational Build Forge Fix Pack 5 (8.0.0.5) for 8.0
Rational Build Forge Fix Pack 6 (8.0.0.6) for 8.0
Rational Build Forge Fix Pack 7 (8.0.0.7) for 8.0
Rational Build Forge Fix Pack 8 (8.0.0.8) for 8.0
Rational Build Forge Fix Pack 9 (8.0.0.9) for 8.0
Rational Build Forge Fix Pack 10 (8.0.0.10) for 8.0
Rational Build Forge Interim Fix 1 for 8.0.0.10
Rational Build Forge Fix Pack 11 (8.0.0.11) for 8.0
Rational Build Forge Interim Fix 1 for 8.0.0.11
Rational Build Forge Fix Pack 12 (8.0.0.12) for 8.0
Rational Build Forge Fix Pack 13 (8.0.0.13) for 8.0
Rational Build Forge Fix Pack 14 (8.0.0.14) for 8.0
Rational Build Forge Fix Pack 15 (8.0.0.15) for 8.0
Rational Build Forge Interim Fix 1 for 8.0.0.15
Rational Build Forge Fix Pack 16 (8.0.0.16) for 8.0
Rational Build Forge Fix Pack 17 (8.0.0.17) for 8.0
Rational Build Forge Fix Pack 19 (8.0.0.19) for 8.0
Rational Build Forge Fix Pack 18 (8.0.0.18) for 8.0
Rational Build Forge Fix Pack 20 (8.0.0.20) for 8.0
Rational Build Forge Fix Pack 21 (8.0.0.21) for 8.0
Rational Build Forge Fix Pack 22 (8.0.0.22) for 8.0
APAR status
Closed as unreproducible in next release.
Error description
Restart job displays wrong step state when conditional step is false. It ticks true-part even the condition was false and else-part ran. Restart job should un-tick true-part because it skipped and else-part was chosen. This problem only happens when true-part contains inline project. It also true-part commands copied into else-part,and true-part and else-part display same commands of true-part. This problem happens no matter inlined projects is linked. Reproduce steps; step1 - conditional and make it false (condition true(1==2) true-part: contains inline project that just one step echo echo I am true-part else-part echo I am else-part step2: just echo
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * None * **************************************************************** * PROBLEM DESCRIPTION: * * Restart job displays wrong step state when conditional step * * is * * false. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Not reproducible on Build Forge 8.0.0.3
Temporary fix
Comments
APAR Information
APAR number
PI30480
Reported component name
RATIONAL BUILDF
Reported component ID
5724S2700
Reported release
800
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-11-27
Closed date
2015-11-12
Last modified date
2016-02-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATIONAL BUILDF
Fixed component ID
5724S2700
Applicable component levels
R800 PSY
UP
Document Information
Modified date:
04 May 2022