Error description

  • When the proxy makes a request from the RUI which contains a
    cookie header and the proxy receives a 302 redirect from the
    server which contains a new Set-Cookie header, the proxy follows
    the 302 by making a new request to the server. However, this new
    request only contains the cookies from the Set-Cookie header of
    the 302 response. The second request from the proxy should
    contain all cookies, with the new values returned by the server
    Set-Cookie overriding any cookie values
    originally sent by the RUI.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * If the server side redirect the request and doesn't response *
    * the cookies, the following request will fail                 *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Cookies will be overwrited when redirect happens in rui      *
    * proxy                                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • RUI proxy will not overwrite the cookies, all the non-duplicated
    cookies will be sent to server side
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI28802

  • Reported component name

    RATL BUS DEV

  • Reported component ID

    5724S5000

  • Reported release

    901

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-10-31

  • Closed date

    2015-03-23

  • Last modified date

    2015-03-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL BUS DEV

  • Fixed component ID

    5724S5000

Applicable component levels

  • R801 PSY

       UP

  • R851 PSY

       UP

  • R901 PSY

       UP

  • R911 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
14 October 2021