Fixes are available
Rational Test Virtualization Server Fix Pack 1 (8.7.0.1) for 8.7
Rational Integration Tester Fix Pack 1 (8.7.0.1) for 8.7
Rational Performance Test Server Fix Pack 2 (8.7.0.2) for 8.7
Rational Integration Tester Fix Pack 2 (8.7.0.2) for 8.7
Rational Test Virtualization Server Fix Pack 2 (8.7.0.2) for 8.7
Rational Test Virtualization Server Fix Pack 3 (8.7.0.3) for 8.7
Rational Integration Tester Fix Pack 3 (8.7.0.3) for 8.7
Rational Performance Test Server Fix Pack 1 (8.7.0.1) for 8.7
Rational Integration Tester Fix Pack 4 (8.7.0.4) for 8.7
Rational Test Virtualization Server Fix Pack 4 (8.7.0.4) for 8.7
Rational Performance Test Server Fix Pack 4 (8.7.0.4) for 8.7
Rational Performance Test Server Fix Pack 3 (8.7.0.3) for 8.7
APAR status
Closed as program error.
Error description
By default the SWIFT Input message type is used in the message editor when applying the SWIFT schema. Attempts to change to Output type give a damaged message with red crosses and missing Application node. STEPS TO REPRODUCE: 1. Apply the MT103 message schema to a text message. 2. Right-click on Application > Type > Application > MT103 Output The Input fields remain and are under a blank Message node with red crosses on additional added fields. WORKAROUND: 1. Remove the Application node. 2. Re-add the Output type Application node.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All users of Rational Integration Tester working with SWIFT * * messages. * **************************************************************** * PROBLEM DESCRIPTION: * * The SWIFT message type defaults to Input in the message * * editor. Changing the message type to Output resulted in a * * damaged message. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
This issue has been fixed, with the following behavior: * If the schema for the new type defines a fixed value for a field, that fixed value is used * The name of the root node is taken from the new type * The user has the choice to include optional fields for the new type
Temporary fix
Comments
APAR Information
APAR number
PI27696
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
851
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-10-15
Closed date
2015-07-14
Last modified date
2015-07-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSN
UP
R870 PSY
UP
Document Information
Modified date:
16 October 2021