IBM Support

PI27421: IF TWO CONFIGURATIONS ARE INSTALLED ON SAME LIBERTY SERVER AND ONE IS REMOVED FROM THE SE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • With the server config tool, on a Liberty Server
    
      - Install 2 configuraitons
        Configuration 1 and configuration 2 with different context
    root
        for the admin and the console
      - Start the Liberty server - verify you can access both
      - Stop the Liberty server
      - Remove configuration 1 from server
      - Start the Liberty server, try to access configuration 2
        then Configuration 2 is not available
    
    Cause of problem:
       usr\servers\<serverName>\apps\worklightadmin.war
    and
       usr\servers\<serverName>\apps\worklightconsole.war
    
    have been removed from the server. That is above two war fiels
    are used by two applications. But they are removed when
    the first configuration is uninstalled.
    
    Reference: RTC defect#: 53809
    

Local fix

  • The workaround would be to re-copy again the WAR file
    after the configuration 1 is removed.
    They are located in <WorklightInstallDir>/WorklightServer
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Administrators and developers deployng multiple Worklight    *
    * configurations on the same Liberty Server with the Server    *
    * Configuration Tool or with ant tasks.                        *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * The uninstallof a Worklight configuration removes all WAR    *
    * files installed at install time. In the case of multiple     *
    * configurations, the WAR files of the console and admin       *
    * service are shared between multiple configurations.          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * -                                                            *
    ****************************************************************
    

Problem conclusion

  • WAR files shared by other installed applications are not removed
    when a configuration is uninstalled.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI27421

  • Reported component name

    WORKLIGHT ENTER

  • Reported component ID

    5725I4300

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-10-10

  • Closed date

    2014-10-29

  • Last modified date

    2014-10-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WORKLIGHT ENTER

  • Fixed component ID

    5725I4300

Applicable component levels

  • R620 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
17 October 2021