IBM Support

PI26452: UNLOAD UTILITY SPANNED YES ON LOB TABLESPACE LOOPING IN DSNUULMB.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • An UNLOAD of a LOB tablespace with SPANNED YES got into a loop
    and never ends.
    The Unload dataset is on tape but the problem also happens
    using vtape.
    At the time of the dump the job is still positioned on first
    tape volume but appears not to write anything.
    Console dump analysis showed the loop being in DSNUULMB between
    offsets +ABA and +CF6 (level UK94806). It looks an internal
    variable went negative when blksize is greater than 32767 .
    

Local fix

  • Manually specify a BLKSIZE less than 32K for the unload
    dataset (or disable LBI Large Block Interface for datasets) .
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All DB2 10 for z/OS and DB2 11 for z/OS      *
    *                 users of the UNLOAD utility with SPANNED     *
    *                 YES and SYSREC on TAPE utilizing Large       *
    *                 Block Interface (LBI).                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: Endless loop during an UNLOAD utility   *
    *                      with SPANNED YES and the unload         *
    *                      (SYSREC) data set is on TAPE and        *
    *                      using Large Block Interface (LBI).      *
    ****************************************************************
    * RECOMMENDATION: Apply corrective PTF when available          *
    ****************************************************************
    An UNLOAD SPANNED YES utility of a LOB table space went into an
    endless loop and had to be cancelled.  The unload SYSREC data
    set was on TAPE and TAPEBLKSZLIM=65535 was set in SYS1.PARMLIB
    to utilize LBI.  UNLOAD SPANNED YES does not support the Large
    Block Interface and will now ignore a block size that is greater
    than 32 KB.
    

Problem conclusion

  • UNLOAD SPANNED YES utility code has been modified to ignore the
    Large Block Interface for the SYSREC data set on TAPE.  The
    data set will utilize system determined blocksize (SDB) and
    the records will continue to be written in the variable blocked
    spanned format.
    
    The Utility Guide and Reference manual has been updated to
    document that UNLOAD SPANNED YES ignores the Large Block
    Interface.  It will be added to the following sections:
    
    Data sets that online utilities use
    UNLOAD utility under the SPANNED keyword
    UNLOAD utility under Unloading data in spanned record format
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI26452

  • Reported component name

    DB2 OS/390 & Z/

  • Reported component ID

    5740XYR00

  • Reported release

    A10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-09-25

  • Closed date

    2014-12-22

  • Last modified date

    2015-02-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI24205 UI24206

Modules/Macros

  •    DSNUGSDA DSNUULDB
    

Fix information

  • Fixed component name

    DB2 OS/390 & Z/

  • Fixed component ID

    5740XYR00

Applicable component levels

  • RA10 PSY UI24205

       UP15/01/21 P F501

  • RB10 PSY UI24206

       UP15/01/21 P F501

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEPEK","label":"Db2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
06 May 2020