IBM Support

PI25569: MSGDSNT376I AND MSGDSNT501I ARE ISSUED WHEN TIME OUT OCCURS INVOLVING RTS DAEMON 014.RTSTST00

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • MSGDSNT376I is issued for time out between an application and
    RTS daemon accessing a user database.  MSGDSNT501I follows with
    a reason code 00C9008E.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All DB2 10 for z/OS and DB2 11 for z/OS      *
    *                 customers.                                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: MSGDSNT376I is issued when an RTS       *
    *                      daemon fails to release a row level     *
    *                      lock on RTS catalog table,              *
    *                      SYSIBM.SYSTABLESPACESTATS or            *
    *                      SYSIBM.SYSINDEXSPACESTATS.              *
    *                      MSGDSNT501I may follow with reason      *
    *                      code 00C9008E.                          *
    ****************************************************************
    * RECOMMENDATION: Apply corrective PTF when available.         *
    ****************************************************************
    DSNT376I with CORRELATION-ID=014.RTSTST00 and DSNT501I
    with RC00C9008E are issued for a time out when an RTS daemon
    fails to release a row level lock on RTS catalog tables
    SYSIBM.SYSTABLESPACESTATS or SYSIBM.SYSINDEXSPACESTATS.
    
    The problem occurs because an internal variable is
    inadvertently set to 'BCT' when it should remain as 'RTS'.
    
    This causes the daemon to not release the lock at a commit.
    Because the RTS daemon continues to hold on to the lock, when
    others attempt to get a lock on the same row, time out occurs
    and the messages are issued.
    
    Additional Keywords: Real-time Statistics
    

Problem conclusion

  • The internal variable setting for RTS daemon has been corrected.
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    PI25569

  • Reported component name

    DB2 OS/390 & Z/

  • Reported component ID

    5740XYR00

  • Reported release

    B10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-09-11

  • Closed date

    2014-12-10

  • Last modified date

    2015-01-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI23773 UI23774

Modules/Macros

  •    DSNIRTSU
    

Fix information

  • Fixed component name

    DB2 OS/390 & Z/

  • Fixed component ID

    5740XYR00

Applicable component levels

  • RA10 PSY UI23773

       UP14/12/30 P F412 Ž

  • RB10 PSY UI23774

       UP14/12/30 P F412 Ž

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEPEK","label":"Db2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: