PI25541: USING .BSET SELECTOR TO CHANGE INLINE SELECTOR ALSO CHANGES BUILD SELECTOR FOR RESTART

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When using .bset selector under a project step that inline
    another project, the selector configured is set as the build
    selector used during restart.
    The correct selector will be used to for the initial build runs,
    were the appropriate selector is used for the project steps and
    the inline steps used the selector configured under .bset
    selector.
    
    Steps to reproduce:
    
    - Create 2 projects (ProjA, ProjB) and two selectors (SelectorA,
    SelectorB).
    - Set ProjA to use SelectorA and with 4 steps.
    - Configure steps 1, 3, and 4 to perform a ".sleep 0"
    - Configure step 2 to perform a ".bset selector SelectorB" and
    to inline ProjB.
    - Execute ProjA build.
    
    Expected result:
    
    - All of ProjA steps run under SelectorA, inlined ProjB steps
    run under SelectorB.
    - When attempting to restart ProjA, the configured selector
    under the Job Start page list "SelectorA".
    
    
    Actual result:
    
    - When attempting to restart ProjA, the configured selector
    under the Job Start page list "SelectorB" instead of
    "SelectorA".
    
    Workaround:
    
    - When restarting the build, modify the build selector under the
    Job Start page to "SelectorA".
    

Local fix

  • When restarting the build, modify the build selector under the
    Job Start page to "SelectorA".
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * ALL                                                          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * USING .BSET SELECTOR TO CHANGE INLINE SELECTOR ALSO CHANGES  *
    * BUILD SELECTOR FOR RESTART                                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The issue was fixed in Build Forge 8.0.0.3 release
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI25541

  • Reported component name

    BUILD FORGE EE

  • Reported component ID

    5724S2701

  • Reported release

    713

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-09-11

  • Closed date

    2016-02-22

  • Last modified date

    2016-02-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    BUILD FORGE EE

  • Fixed component ID

    5724S2701

Applicable component levels

  • R713 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSB2MV","label":"Rational Build Forge"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1.3","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
03 May 2022