Fixes are available
APAR status
Closed as program error.
Error description
Some tests that passed with GH Tester now fail when running in Rational Integration Tester (RIT). The first iteration of a test after starting RIT might work but subsequent ones fail. In GH Tester, HTTP connections are created for each action. In RIT, HTTP connections are pooled and are re-used to improve performance. For systems that expect new connections the RIT connection pooling causes problems.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * A small number of users of Rational Integration Tester * * working with HTTP. * **************************************************************** * PROBLEM DESCRIPTION: * * Users experienced changes in HTTP connection behavior when * * upgrading from Green Hat Tester version 5.x to Rational * * Integration Tester 8.x * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
A start-up option has been added to turn off HTTP connection pooling, which reverts behavior to that in Green Hat Tester 5.x. Use of this option does reduce performance and should only be used on the advice of IBM Support. The start-up option can be specified in Library Manager for Rational Integration Tester and the Rational Integration Tester Agent (for Rational Test Virtualization Server or Rational Performance Test Server customers) and consists of the following string: -Dgreenhat.http.pooling.off=true
Temporary fix
Comments
APAR Information
APAR number
PI25505
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
851
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-09-11
Closed date
2015-06-25
Last modified date
2015-06-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSY
UP
R860 PSY
UP
R870 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5.1","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: