A fix is available
APAR status
Closed as program error.
Error description
You were experiencing SOS above the line. The region was found to contain muliple CEMT task all waiting on storage. You are receiving DFHZC2404 (VTAM detected an error in a request) followed by: DFHZC0001 An abend (code ---/AKEG) has occurred at offset X'2BFE' in module DFHZGTA. CICS then continued with repeated with 0C4 in DFHZGTA: DFHZC0001 An abend (code 0C4/AKEA) has occurred at offset X'FFFF' in module DFHZGTA. As the errors continued, there was also an AKEG in DFHTBSB DFHAP0001 An abend (code ---/AKEG) has occurred at offset X'00000AFA' Then, later, you received the failures in MVS GETMAINS. DFHME0006 Insufficient storage to satisfy GETMAIN (code x'0342') in module DFHMEME. MVS code 0004. The region eventually has to be cancelled. . ZC0001 dump shows the task running in error is CATA. . Looking into the last abend0C4/AKEA. Program DFHZGTA was in control, but the PSW was elsewhere. Error happened under the CICS RB. . CICS Registers and PSW PSW: 078D0001 80000000 00000000 000150E1 Instruction Length: 2 Interrupt Code: 38 Exception Address: 000A0000_00015800 Execution key at Program Check/Abend: 8 Addressing Mode: 64 Space at Program Check/Abend: Basespace Breaking Event Address: 00000000_1EC5A93C - offset 0000033C in module DFHZGTA 64-BIT REGISTERS 0-15, R0: 0000028A 1398 bytes of storage addressable R1: 00876B5D 25763 bytes of storage addressable R2: 00000000 2048 bytes of storage addressable R3: 1EC5A600 Module DFHZGTA + X'0' R4: 008761A8 KE STACK Entry, TranNum n/a . Module ........ + X'0' R5: 1EC5B5FF Module DFHZGTA + X'FFF' R6: 1EC5C5FE Module DFHZGTA + X'1FFE' R7: 1EC5D5FD Module DFHZGTA + X'2FFD' R8: 1EC5E5FC Module DFHZGTA + X'3FFC' R9: 1EC5F5FB Module DFHZGTA + X'4FFB' R10: 1EC605FA Module DFHZGTA + X'5FFA' R11: 1DCC1990 SM Domain Table Entry + X'190' R12: 22517700 Task 46435 User TCA + X'0' R13: 1DCC1990 SM Domain Table Entry + X'190' R14: A0000_000150E1 Storage invalid R15: 00000000 2048 bytes of storage addressable . Further diagnosis, the problem is that CICS picks up a bad value of KERNPOWN in DFHZGTA HCI6700 at offset x'330' for CATA. This leads to abend0C4 at offset x'33C' where we did 0B0E or BSM 0,14 r14: A0000_000150E1 contains an invalid branch address. . Additional Symptom(s) Search Keyword(s): KIXREVSWM
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS users. * **************************************************************** * PROBLEM DESCRIPTION: Abend 0C4 occurs following an abend * * when DFHZGTA is in control. * **************************************************************** * RECOMMENDATION: * **************************************************************** An abend occurs when DFHZGTA is running. This results in the recovery routine being driven. On exit from the recovery routine, control is passed to the module exit point. If register 11, which is used as a saved stack address, has become invalid, DFHZGTA will experience an 0C4 abend.
Problem conclusion
DFHZGTA has been changed so that the saved stack address is correct before control is passed to the module exit point.
Temporary fix
FIX AVAILABLE BY PTF ONLY
Comments
APAR Information
APAR number
PI23365
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
800
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / CST / Xsystem
Submitted date
2014-08-06
Closed date
2014-08-13
Last modified date
2015-03-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI20479 UI20480
Modules/Macros
DFHZGTA
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400