IBM Support

PI22766: FS 90 CAUSES FILE DELETION

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Variable block file with minimum length of 813 bytes and maximum
    length 1968 gets delete defined with different attributes,
    when the file is open in CICS and a batch program tries to open
    it in OUTPUT mode.
    

Local fix

  • N/A
    

Problem summary

  • USERS AFFECTED:
    Clients with SFS files being accessed concurrently via COBOL
    programs and TxSeries transactions may be affected by this
    issue.
    
    PROBLEM DESCRIPTION:
    Opening a SFS file for OUTPUT does a delete/create instead of
    empty.  This caused increased CPU and elapsed time there by
    enlarging a window for errors in concurrent execution.
    The centre of the issue is concurrent execution (COBOL batch and
    CICS ONLINE), and timing window wherein a COBOL OPEN OUTPUT does
    a DELETE and then a CREATE.
    A CICS transaction can catch us between the DELETE and CREATE
    and fail.
    

Problem conclusion

  • SFS files opened for OUTPUT will now empty the file instead of
    doing a delete/create.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI22766

  • Reported component name

    COBOL FOR AIX

  • Reported component ID

    5724Z8700

  • Reported release

    411

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-07-28

  • Closed date

    2014-09-25

  • Last modified date

    2014-09-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    COBOL AIX RUNTI

  • Fixed component ID

    5724Z8702

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SGM","label":"COBOL for AIX"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"411","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information