Fixes are available
Rational Integration Tester Fix Pack 1 (8.6.0.1) for 8.6
Rational Test Virtualization Server Fix Pack 1 (8.6.0.1) for 8.6
Rational Performance Test Server Fix Pack 1 (8.6.0.1) for 8.6
Rational Integration Tester Fix Pack 2 (8.6.0.2) for 8.6
Rational Performance Test Server Fix Pack 2 (8.6.0.2) for 8.6
Rational Test Virtualization Server Fix Pack 2 (8.6.0.2) for 8.6
Rational Integration Tester Fix Pack 3 (8.6.0.3) for 8.6
Rational Performance Test Server Fix Pack 3 (8.6.0.3) for 8.6
Rational Test Virtualization Server Fix Pack 3 (8.6.0.3) for 8.6
Rational Integration Tester Fix Pack 4 (8.6.0.4) for 8.6
Rational Performance Test Server Fix Pack 4 (8.6.0.4) for 8.6
Rational Test Virtualization Server Fix Pack 4 (8.6.0.4) for 8.6
APAR status
Closed as program error.
Error description
If an application specifies MQPM_NEW_MESG_ID in its Put configuration, a new message ID is generated. Sift and pass through is incorrectly applying this setting to the new message on the divert queue which causes the message IDs to no longer correlate.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All users of Rational Integration Tester with MQ * **************************************************************** * PROBLEM DESCRIPTION: * * In version 8.6.0 of Rational Integration Tester, a problem * * was introduced that meant if an application "put" a message * * to an MQ queue using the MQPMO_NEW_MSG_ID option (to force a * * new message ID to be generated), then sift-and-pass-through * * functionality would not work correctly in stubs for that * * message. The following message would be displayed in the * * RIT console: * * * * [CRRIT3114E] Failed to process finishUpStub * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
This problem has been fixed in Rational Integration Tester 8.6.0.1. It only exists in the 8.6.0 version; previous versions are unaffected.
Temporary fix
Comments
APAR Information
APAR number
PI22396
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
860
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-07-21
Closed date
2014-09-01
Last modified date
2014-09-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R860 PSY
UP
Document Information
Modified date:
15 October 2021