A fix is available
APAR status
Closed as program error.
Error description
V5.1.1 compile gives errors: IGYCB7104-U Internal error while compiling function xxxxxxxx. Failed assertion on ./COBOLPerfGraph.cpp:526. Compilation terminated. or IGYCB7104-U Internal error while compiling function xxxxxxxx. Failed assertion on ./COBOLPerfGraph.cpp:1634. Compilation terminated. The compiler returns the error(s) under optimization values, OPT(1/2).
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of COBOL V5 compiling programs that * * contain pairs of PERFORM ranges that are not * * strictly recursive but are close. E.g., * * PERFORM A THRU C. Where A does a PERFORM D. * * and D does a PERFORM B THRU C. * * * **************************************************************** * PROBLEM DESCRIPTION: IGYCB7104-U Internal error while * * compiling function xxxxxxx. Failed * * assertion on ./COBOLPerfGraph.cpp:526. * * Compilation terminated. * * * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * * * **************************************************************** PERFORM inlining optimization should not be done when there is the possibility of recursion, but in this case the compiler was trying to inline something that caused a failure later on.
Problem conclusion
The compiler was changed to handle these cases correctly (and limit PERFORM inlining accordingly).
Temporary fix
Comments
APAR Information
APAR number
PI20532
Reported component name
ENT COBOL FOR Z
Reported component ID
5655W3200
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-06-20
Closed date
2014-07-22
Last modified date
2014-08-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGYCBE
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655W3200
Applicable component levels
R510 PSY UI19849
UP14/07/25 P F407
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1","Edition":"","Line of Business":{"code":"LOB17","label":"Mainframe TPS"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1","Edition":"","Line of Business":{"code":"","label":""}}]