IBM Support

PI20532: V5.1 COMPILE ERROR IGYCB7104-U: FAILED ASSERTION ON ./COBOLPERFGRAPH.CPP:526 or ./COBOLPerfGraph.cpp:1634.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • V5.1.1 compile gives errors:
    IGYCB7104-U Internal error while compiling function xxxxxxxx.
    Failed assertion on ./COBOLPerfGraph.cpp:526.
    Compilation terminated.
    or
    IGYCB7104-U Internal error while compiling function xxxxxxxx.
    Failed assertion on ./COBOLPerfGraph.cpp:1634.
    Compilation terminated.
    
    The compiler returns the error(s) under optimization values,
    OPT(1/2).
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of COBOL V5 compiling programs that    *
    *                 contain pairs of PERFORM ranges that are not *
    *                 strictly recursive but are close.  E.g.,     *
    *                 PERFORM A THRU C.  Where A does a PERFORM D. *
    *                 and D does a PERFORM B THRU C.               *
    *                                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: IGYCB7104-U  Internal error while       *
    *                      compiling function xxxxxxx.  Failed     *
    *                      assertion on ./COBOLPerfGraph.cpp:526.  *
    *                      Compilation terminated.                 *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    *                                                              *
    ****************************************************************
    PERFORM inlining optimization should not be done when there is
    the possibility of recursion, but in this case the compiler was
    trying to inline something that caused a failure later on.
    

Problem conclusion

  • The compiler was changed to handle these cases correctly (and
    limit PERFORM inlining accordingly).
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI20532

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655W3200

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-06-20

  • Closed date

    2014-07-22

  • Last modified date

    2014-08-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGYCBE
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655W3200

Applicable component levels

  • R510 PSY UI19849

       UP14/07/25 P F407

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1","Edition":"","Line of Business":{"code":"LOB17","label":"Mainframe TPS"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
04 August 2014