PI18925: ATTEMPTS TO OPEN A MESSAGING TEST ACTION FAIL WITH NO ERROR MESSAGE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If you try to open a messaging action such as Publish or
    Subscribe when you do not have the required library files
    nothing happens.  No error message is displayed.
    
    If you click Help > About > JVM Console you will see an error
    such as the following:
    
    java.lang.NoClassDefFoundError:
    com.wm.app.b2b.client.ServiceException
    
    SOLUTION:
    
    1. Run Library Manager to configure the necessary library files
    2. Re-start RIT and load the project
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users of Rational Integration Tester working with        *
    * messaging tests.                                             *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * If the user opened a messaging test action such as Publish   *
    * or Subscribe, but did not have the required library files in *
    * Library Manager, no error message was displayed to indicate  *
    * that the action was unable to complete.                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • A fix for this issue was provided in version 8.7.0 of Rational
    Integration Tester. An error message is now displayed concerning
    the missing library files.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI18925

  • Reported component name

    RATL TEST WORKB

  • Reported component ID

    5725G7900

  • Reported release

    851

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-05-29

  • Closed date

    2015-05-21

  • Last modified date

    2015-05-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL TEST WORKB

  • Fixed component ID

    5725G7900

Applicable component levels

  • R800 PSN

       UP

  • R801 PSN

       UP

  • R850 PSN

       UP

  • R851 PSN

       UP

  • R860 PSN

       UP

  • R870 PSY

       UP