A fix is available
APAR status
Closed as program error.
Error description
A "NullPointerException" error may occur when building a project that was imported from 5.0.6.x into 6.1 The problem only occurs in Windows. Additional Keywords: Worklight Versions Affected: 6.1.x Initial Impact: High
Local fix
1) Delete the previously imported project from Eclipse (including from the file system) 2) Close Eclipse 3) Run this command in command line: "rd %temp%\wlBuildResources /Q/S" 4) Open Eclipse 5) Import the 5.0.6.1 project 6) Clean without rebuilding immediately 7) Close Eclipse 8) Run this command in command line: "rd %temp%\wlBuildResources /Q/S" 9) Open Eclipse 10) Build the environment
Problem summary
**************************************************************** * USERS AFFECTED: * * Worklight developers with hybrid applications that have * * skins for only some environments. * **************************************************************** * PROBLEM DESCRIPTION: * * The user receives a NullPointerException after importing a * * Worklight project or making a change to a resource under a * * hybrid application's folder. The user may also notice that * * changes may not be reflected immediately in the Mobile * * Browser Simulator after this. * **************************************************************** * RECOMMENDATION: * * - * ****************************************************************
Problem conclusion
The code was modified so that an environment not having a skin will not lead to this failure. No further action needs to be taken after installing the fix.
Temporary fix
Comments
APAR Information
APAR number
PI18029
Reported component name
WORKLIGHT ENTER
Reported component ID
5725I4300
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-05-15
Closed date
2014-08-25
Last modified date
2014-08-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WORKLIGHT ENTER
Fixed component ID
5725I4300
Applicable component levels
R610 PSY
UP
R620 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: