APAR status
Closed as program error.
Error description
RFT 8.5.1 - Playback fails with ObjectNotFoundException on SAP GUI. The SAPGUI application has been enabled correctly and the recording is fine however the playback results in ObjectNotFoundException while performing any action on any control of SAPGUI.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users trying to automate SAP GUI for Windows 7.2 ( Enabled * * client in RFT) * **************************************************************** * PROBLEM DESCRIPTION: * * From SAP GUI windows application, some of the controls are * * getting recognized as windows controls and some as SAP * * controls. However during playback RFT is unable to find * * these controls and throwing ONF exception. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
RFT 8513 contains the fix. When the SAP GUI is launched from saplgpad or sapgui.exe, the enablement of the application should be successful and record and playback should work as expected. ObjectNotFound Exceptions should not be seen.
Temporary fix
Comments
APAR Information
APAR number
PI14779
Reported component name
RAT FUNC TESTER
Reported component ID
5724G2503
Reported release
851
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-03-29
Closed date
2014-05-08
Last modified date
2014-10-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
domain
Fix information
Fixed component name
RAT FUNC TESTER
Fixed component ID
5724G2503
Applicable component levels
R800 PSN
UP
R800 PSY
UP
R810 PSN
UP
R810 PSY
UP
R811 PSN
UP
R811 PSY
UP
R820 PSN
UP
R820 PSY
UP
R821 PSN
UP
R821 PSY
UP
R822 PSN
UP
R822 PSY
UP
R830 PSN
UP
R830 PSY
UP
R850 PSN
UP
R850 PSY
UP
R851 PSN
UP
R851 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSJMXE","label":"IBM Rational Functional Tester"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
08 October 2014