Fixes are available
APAR status
Closed as program error.
Error description
Rational Developer for System z (RDz): RDz client 8.5.1.4 The Real Time Syntax Check gives errors with PL/I DCL ENTRY *************************************************************** Rational Developer for System z (RDz): RDZ client 8.5.1.4 The Real Time Syntax check gives several errors with the PL/I DCL ENTRY. The Remote Syntax Check and the PL/I compiler do not . Example: DCL USDI004 ENTRY (1, 3 CHAR(1), 3 CHAR(8), 3 CHAR(8), 3 BIN(31,0) UNAL, 3 BIN(31,0) UNAL, 3 BIN(15,0) UNAL, 3 BIN(15,0) UNAL, 3 BIN(15,0) UNAL, 3 BIN(15,0) UNAL, 3 BIT(1) ALIGNED, 3 BIT(1) ALIGNED, 3 BIN(15,0) UNAL); The following errors are shown: - ')' inserted to complete the scope? on line 'USDI004 ENTRY (1, 3 CHAR (1),' - ',StructDescrPartRepeatable' inserted to complete scope ')'on line '3 BIN(31,0) UNAL,' - 'ERROR_TOKEN' unexpected token(s) ignored ? on line '3 BIN(15,0) UNAL);'. *************************************************************** Local fix None
Local fix
Problem summary
RDz's PL/I Parser did not accept alignment attributes in entry descriptions.
Problem conclusion
Modified RDz's PL/I Parser to accept alignment attributes in entry descriptions. The problem listed in this APAR has been resolved with IBM Rational Developer for System z V8.5.1.5 Fix Pack which is available from the Recommended Fixes support download page: http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
Temporary fix
Comments
APAR Information
APAR number
PI14637
Reported component name
RATL DEV FOR SY
Reported component ID
5724T0700
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-03-27
Closed date
2014-06-27
Last modified date
2014-06-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL DEV FOR SY
Fixed component ID
5724T0700
Applicable component levels
R851 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSTRMM","label":"IBM Developer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"850","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: