Error description

  • null pointer exception due to a missing of extractor name
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Worklight developers that use multiple adapters of the same  *
    * type                                                         *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * When mulitple adapters of the same type are deployed,        *
    * removing one of the adapters would cause all the other       *
    * deployed adapters of the same type to malfunction.           *
    *                                                              *
    * One of the triggering scenario is as follows:                *
    *                                                              *
    * 1. deploy http adapter 'A'                                   *
    * 2. ensure invoke procedure of adapter 'A' is functioning -   *
    * this can be tested by application on device or by simulating *
    * the client (jmeter)                                          *
    * 3. deploy http adapter 'B'                                   *
    * 4. procedure invocation should not be lost yet               *
    * 5. delete adapter 'B'                                        *
    * 6. invoke procedure ability is now lost with null            *
    *                                                              *
    * And the following mesage is received.                        *
    * [3/9/14 10:11:35:471 GMT] 00000163                           *
    * com.worklight.integration.model.InvocationContext            *
    * E FWLSE0099E: An error occurred while invoking procedure     *
    * [project perftest]baseline/HttpRequestFWLSE0100E:            *
    * parameters: [project perftest]                               *
    * null                                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * -                                                            *
    ****************************************************************
    

Problem conclusion

  • The issue has been fixed by adding proper checking during
    deletion of one adapter so that the deletion doesn't remove
    rersources needed by other adapters of the same type.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI13334

  • Reported component name

    WORKLIGHT CONSU

  • Reported component ID

    5725I4301

  • Reported release

    600

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-03-09

  • Closed date

    2014-04-06

  • Last modified date

    2014-04-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WORKLIGHT CONSU

  • Fixed component ID

    5725I4301

Applicable component levels

  • R506 PSY

       UP

  • R600 PSY

       UP

  • R610 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"600","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
17 October 2021