IBM Support

PI09913: WORKLIGHT UNDER HIGH VOLUMES SHOWS MEMORY INCREASE WHEN REPORTING ENABLED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When reporting is enabled and the Worklight server is placed
    under load, the memory profile increases as time passes.  If
    reporting is disabled, the issue does not occur.
    

Local fix

  • Use the WebSphere Analytics Platform or disable reporting.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Administrators or developers that use the Reports Database   *
    * and BIRT reports.                                            *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * A server-side memory leak appears if there are a large       *
    * number of report activities due to an issue with OpenJPA     *
    * when persisting report data to the database.                 *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * -                                                            *
    ****************************************************************
    

Problem conclusion

  • The code was modified so that OpenJPA is correctly configured
    and the memory leak will no longer occur.
    
    The fix for this APAR is currently targeted for inclusion in
    fixpack 6.0.0.2 and fixpack 6.1.0.1.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI09913

  • Reported component name

    WORKLIGHT CONSU

  • Reported component ID

    5725I4301

  • Reported release

    600

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-01-18

  • Closed date

    2014-03-25

  • Last modified date

    2014-03-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WORKLIGHT CONSU

  • Fixed component ID

    5725I4301

Applicable component levels

  • R600 PSY

       UP

  • R610 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"600","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
16 October 2021