APAR status
Closed as program error.
Error description
IBM Developer for z/OS Remote Connection Emulator is clearing command line contents. When entering into TSO OMVS with a UNIX prompt and something is entered in the command line, the content of the command line is wiped out.
Local fix
Problem summary
IN RCE, when a command is entered in OMVS, the status text at the bottom right of the screen will show RUNNING. After some time elapses (about 10 seconds) the screen updates from RUNNING to INPUT. When the screen update occurs, any text the user has typed in the command will be cleared out.
Problem conclusion
In RCE, when a command is entered in OMVS, the status text at the bottom right of the screen will show RUNNING. After some time elapses (about 10 seconds) the screen updates from RUNNING to INPUT. When the screen update occurs, any text the user has typed in the command will be cleared out. Screen buffering has been implemented so that screen updates are paused after a user modifies a field, then screen updates are resumed (and played back) after a submit (or attention identifier) action. This causes the user's input to no longer be cleared out on the OMVS page after a user enters a command immediately following another command.
Temporary fix
Comments
APAR Information
APAR number
PH54117
Reported component name
DEV FOR Z/OS
Reported component ID
5724T0700
Reported release
G00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-04-24
Closed date
2023-06-16
Last modified date
2023-06-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DEV FOR Z/OS
Fixed component ID
5724T0700
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSJK49","label":"IBM Developer for z Systems"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"G00"}]
Document Information
Modified date:
16 June 2023