APAR status
Closed as program error.
Error description
In IDz v15.0.x users noticed while using the COBOL editor's option at Window->Preferences->COBOL->Editor->Save Actions, the COBOL editor always does all formatting to the source code even if "apply only capitalization options" is selected. Workaround: Go to Window->Preferences->COBOL->Editor->Formatter and uncheck "Enable indentation of..." at the Data Division and the Procedure Division section.
Local fix
N/A
Problem summary
Recent refactoring of the COBOL formatter ignored the On-Save preferences.
Problem conclusion
Corrected the logic to take these preferences into account when formatting on save.
Temporary fix
Comments
APAR Information
APAR number
PH52058
Reported component name
DEV FOR Z/OS
Reported component ID
5724T0700
Reported release
F00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-01-20
Closed date
2023-05-19
Last modified date
2023-05-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DEV FOR Z/OS
Fixed component ID
5724T0700
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSJK49","label":"IBM Developer for z Systems"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"F00"}]
Document Information
Modified date:
19 May 2023