PH46450: ZD&T 13.X EE: EMULATOR NOT ALWAYS STARTING AFTER MULTIPLE STOP/START API REQUESTS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible.

Error description

  • ZD&T 13.X EE
    
    After a successful deployment, a series of Stop/Start API
    requests are issued approximately 3-4 minutes apart.
    Half of the Start API requests fail.
    
    The logs indicate duplicate IPL Handling scripts running on the
    target Linux host resulting in a z/OS Wait state which occurs
    when the oprmsg 'v cn(*),activate" command is issued prior to
    IEE389I.
    

Local fix

  • 1. After any Start API request, wait at least 15 minutes prior
    to executing any subsequent Start API request. This wait time is
    
    regardless of a successful connection to z/OS. Note that 15
    minutes is an estimate, as there are handling threads running on
    both the target Linux host and the ZD&T Tools server. One may
    have to adjust the wait time upward if errors still persist. It
    is also completely possible to require less time between
    multiple Start API requests, as this is highly dependent on what
    
    z/OS subsystems are starting and the time it takes for ZD&T
    tools to complete any post IPL processing. Generally speaking,
    if the zdt_ipl_handle_log.sh and zdt_ipl.sh processes on the
    target Linux host are complete (i.e. none are running), then it
    is safe to do a new Start API request. Again, there could still
    be a timing issue here if the threads on the ZD&T Tools server
    haven't terminated yet.
    
    2. It may be also be possible to prevent the error without
    waiting so long by killing any zdt_ipl_handle_log.sh and
    zdt_ipl.sh processes running on the target Linux host after any
    Stop API Request and before any subsequent Start API Request.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * ZD&T users                                                   *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * ZD&T 13.X EE: Emulator not always starting after multiple    *
    * stop/start requests                                          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PH46450

  • Reported component name

    ZSYS DEV AND TE

  • Reported component ID

    5725G3900

  • Reported release

    D00

  • Status

    CLOSED UR5

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-05-13

  • Closed date

    2022-12-02

  • Last modified date

    2022-12-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSTQBD","label":"Rational Development and Test Environment for System z"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"D00","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
02 December 2022