APAR status
Closed as program error.
Error description
not presetting SQLERROR can lead to a loop in running a zUnit test case
Local fix
manually set a value in the test case generator
Problem summary
ZUnit - if no test data is set to the DB2 FETCH command, an infinite loop may occur at run time.
Problem conclusion
If there is no recorded data and no input data for the FETCH command and SELECT INTO command, change it to set SQLCODE to 100 in the zUnit test case.
Temporary fix
Comments
APAR Information
APAR number
PH42178
Reported component name
Z/OS EXPLORER E
Reported component ID
5724T0723
Reported release
F00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-11-18
Closed date
2022-03-10
Last modified date
2022-03-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DEV FOR Z/OS
Fixed component ID
5724T0700
Applicable component levels
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSJK49","label":"IBM Developer for z Systems"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"F00"}]
Document Information
Modified date:
11 March 2022