IBM Support

PH41875: IDZ JCL EDITOR OR EXPLORER FOR Z/OS MARKS THE SYSAFF STATEMENT ON THE JOBCARD AS ERROR: "RESTART EXPECTED INSTEAD OF THIS INPUT"

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Using IBM Developer for Z systems - IDz v15.0.1 , a problem
    occurs when the member contains the line
    numbers.
    the JCL Editor of IDz or Explorer for z/OS marks the SYSAFF
    statement on the jobcard as error: "Restart expected instead of
    this input"
    
    Sample:
    
    // REGION=0M,TIME=0,
    // SYSAFF=*,
    // NOTIFY=&SYSUID
    //DUMMY EXEC PGM=IEFBR14
    
    Though JCL editor marks the SYSAFF statement as error, you can
    submit the JCL from IDz or ISPF
    
    It appears that SYSAFF is currently not defined as a JOB parm
    with the grammar as should be the case according to the docs
    

Local fix

Problem summary

  • The JCL Editor of IDz or Explorer for z/OS marks the SYSAFF
    statement on the jobcard as error: "Restart expected instead of
    this input". SYSAFF is currently not defined as a JOB parameter
    in the JCL grammar. You can submit the JCL from IDz or ISPF.
    

Problem conclusion

  • This issue has been resolved.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH41875

  • Reported component name

    DEV FOR Z/OS

  • Reported component ID

    5724T0700

  • Reported release

    F00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-11-04

  • Closed date

    2022-03-10

  • Last modified date

    2022-03-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DEV FOR Z/OS

  • Fixed component ID

    5724T0700

Applicable component levels

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSJK49","label":"IBM Developer for z Systems"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"F00"}]

Document Information

Modified date: