PH30434: IDZ V14.2.2 READ-ONLY PROPERTY IS CHANGED TO UNCHECKED IF A FILEIS OPENED BY EDITOR

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Open z/OS Projects
    New->Other->Examples->Workstation COBOL->COBOL Sample 1
    Input 'Sample1' in Project name and push Finish button
    Select PrintApp.cbl and select Properties in pop-up menu
    Check Read-only and push OK button
    Select PrintApp.cbl and select Properties in pop-up menu
    Read-only still checked,  push OK
    Double click PrintApp.cbl
    Close PrintApp.cbl
    Select PrintApp.cbl and select Properties in pop-up menu
    Read-only is unchecked --> THIS IS THE PROBLEM. SHOUD STAY
    CHECKED
    
    Same happens with
    Window->Perspective->Open Perspective->Other->Resource
    New->Project->General->Project
    ->new->Folder
    ->New->File (even empty)
    After opening the file (even empty), then closing without
    any update, Read-only is unchecked.
    
    occurs in IDz
    Does not occur in IBM Explorer for z/OS, nor standalone
    Eclipse.
    

Local fix

Problem summary

  • On editor close, all files being incorrectly set to read-only in
     an attempt to fix a server side edge case.
    

Problem conclusion

  • No longer setting local files to read only on editor close.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH30434

  • Reported component name

    DEV FOR Z/OS

  • Reported component ID

    5724T0700

  • Reported release

    E20

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-10-12

  • Closed date

    2020-12-04

  • Last modified date

    2020-12-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DEV FOR Z/OS

  • Fixed component ID

    5724T0700

Applicable component levels

[{"Line of Business":{"code":"LOB17","label":"Mainframe TPS"},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSQ2R2","label":"Rational Developer for z Systems"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"E20"}]

Document Information

Modified date:
05 December 2020